Fluke Connect 789 ProcessMeter™ and Temperature Kit

Unique new wireless measurement logging capability;
Temperature measurement from -200 °C to 1372 °C using the t3000 FC;
24 V Loop power supply;
HART mode setting with loop power (adds 250 ohm resistor).

More details

New product
 
More info

Fluke 789 Temperature Kit features:

  • Unique new wireless measurement logging capability
  • Temperature measurement from -200 °C to 1372 °C using the t3000 FC
  • 24 V Loop power supply
  • HART mode setting with loop power (adds 250 ohm resistor)
  • 100 % larger dual display
  • 1200 ohm drive capability on mA source
  • Enhanced backlight with two brightness settings
  • 0 % to 100 % mA Span Check buttons to toggle between 4 and 20 mA
  • Infrared I/O serial port compatible with
  • FlukeView® Forms Software Version 2.1
  • Externally accessible fuses for easy replacement

These 787 features are also included in the 789:

  • DMM designed to meet 1000 volt IEC 1010 CAT III standards
  • Precision 1000 V, 440 mA True-RMS digital multimeter
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode test and continuity beeper
  • Simultaneous mA and % of scale readout
  • 20 mA dc current source/loop calibrator/ simulator
  • Manual Step (100 %, 25 %, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes

Fluke Connect is not available in all countries.

All trademarks are the property of their respective owners. Smart phone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Compatible with iPhone 4x and up running iOS 7 or higher, iPad (in an iPhone frame on iPad) and Galaxy S4, Nexus 5, HTC One running Android™ 4.4.x or higher. Apple and the Apple logo are trademarks of Apple Inc. registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a trademark of Google Inc.

Industrial Technical Services from Mississauga, Ontario is a single source Instrumentation and Automation company. We provide certified calibrations, PLC programming, custom controls and Panels.

 
Specification
Current measurementRange0-1 A AC or DC
Resolution1 mA
Accuracy0.2% + 2 LSD (DC)
Range0-30 mA
Resolution0.001 mA
Accuracy0.05% + 2 lSD
Current sourcingRange0-20 mA or 4-20 mA
Resolution0.05% of span
Drive capability24 V Compliance or 1200 Ω @ 20 mA
Frequencyto 19.999 kHz, 0.005% + 1 LSD
ContinuityBeeps for resistance < 100 Ω
Voltage measurementRange0-1000 V AC (true-rms) or DC
Resolution0.1 mV to 1.0 V
Accuracy0.1% Rdg + 1 LSD (VDC)
Resistance measurementto 40 MΩ, 0.2% + 1 LSD
Diode test2.0 V shoes diode voltage drop
Display current and % of spanYes
Auto Step, Auto RampYes

Environmental Specifications
Operating temperature-20 ºC to 55 ºC
Storage temperature-40 ºC to 60 ºC
Humidity (without condensation)95% up to 30 ºC 
75% up to 40 ºC 
45% up to 50 ºC 
35% up to 55 ºC
Temperature coefficient0.05 x (specified accuracy) per ºC (for temperatures < 18 ºC or > 28 ºC)

Safety Specifications
Electrical safetyDesigned in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92
Overvoltage categoryIEC 1010-1 CAT III 1000 V 
IEC 1010-1 CAT IV 600 V
Maximum voltage1000 V rms

Mechanical and General Specifications
Size50 x 100 x 203 mm (1.25" H x 3.41"W x 7.35" L)
Weight610 g (1.6 lbs)
Batteries4 AA alkaline batteries
Warranty3 years
Battery life140 hours typical (measurement), 10 hours typical (sourcing 20 mA)
Shock and vibrationRandom, 2 g, 5-500 Hz 
1 meter drop test

Fluke t3000 FC Wireless K-Type Temperature Module

General Specifications
Range K-type-200 °C to 1372 °C
Resolution0.1 °C
Accuracy± [0.5 % + 0.5 °C] counts
Input terminalsK-type mini
LCD w/backlight3 ½ digits
Log rate/interval1 sec minimum/adjustable by PC
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Temperature coefficient0.01 % of reading +0.03 °C per °C
Temperature scaleITS-90
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
AltitudeOperating: 2,000 m
Storage: 12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, CAT I, 3rd edition Pollution Degree 2
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years

Note: Not compatible with Fluke CNX test tools