PD560 Nova Temperature Meter

New product
 
More info

The Nova PD560 is a digital meter that accepts a wide variety of process and temperature inputs and is available in 1/8 and 1/4 DIN sizes. Its universal input accepts thermocouple, RTD, and voltage inputs, and it can be easily configured for a 4-20 mA input. It is available with up to three (3) relays, a 4-20 mA analog outputs, two (2) digital inputs, and an RS485 serial communication option which includes protocols for master/slave set point control, Modbus® ASCII and RTU, as well as PC software.

Features

  • Thermocouple, RTD, & Process Inputs
  • Two Ramp & Soak Programs, 15 segments each
  • Universal Power Supply 100-240 VAC
  • Up to 3 Relays & 2 Analog Outputs
  • Digital Input Program Operation
  • RS-485 Serial Communications Option
  • Modbus® RTU/ASCII Communications
  • Free Operating & Data Logging Software
  • IP55 & IP65 Fronts
  • 1/16, 3/16, 1/8, 1/4 DIN Sizes
  • 3 Year Warranty
 
Specifications

Serial Communications

Display: Dual 4 digits, red LED, -1999 to 9999

DIN SIZE PV Display
Inch (mm)
SP Display
Inch (mm)
Weight
oz (g)
1/8 (H) 0.78 (19.8) 0.45 (11.5) 10.0 (285)
1/4 0.81 (20.5) 0.43 (11.0) 13.9 (394)

Front Panel: Panel gasket provided.
1/8 DIN: IP65
1/4 DIN: IP55
Programming Methods: Four front panel buttons and Modbus
Noise Filter: Programmable 1 to 120 seconds, or off
Display Update Rate: 4/second
Max/Min Display: Stored until reset by user or meter is turned off.
Password: Restricts modification of programmed settings.
Non-Volatile Memory: Settings stored for a minimum of 10 years
Power: 100-240 VAC, 50/60 Hz, 10 W
Required Fuse: UL Recognized, 1 A, 250 V, slow-blow
Isolation: 2300 V input/output-to-power line; 4 kV relay output-to-input/output/power line.
Operating Temperature: 10 to 50°C
Storage Temperature: -40 to 85°C
Relative Humidity: 20 to 90% non-condensing
Enclosure: 1/8 & 1/4 DIN available; impact-resistant plastic; color: black
UL File Number: E244207; Process Control Equipment
Approvals: UL & C-UL Recognized, CE Compliant
Warranty: 3 years parts & labor

Temperature Inputs

Inputs: Factory calibrated, field selectable: J, K, T, E, B, R, S, L, U, N, W, and Platinel II thermocouples and 100 Ω (0.00385 or 0.00392 curve)
Cold Junction Reference: Automatic or off
Offset Adjustment: Four programmable input bias zones
Sensor Break: Up or down scale, user selectable; display reads S.OPN; alarm relays will follow the up or down scale selection.

Type Range (°C) Range (°F) Accuracy
K1 -200 to 1370 -300 to 2500 >0ºC: ±0.1% FS ±1 count
<0ºC: ±0.2% FS ±1 count
K2 -199.9 to 999.9 0 to 2300
J -199.9 to 999.9 -300 to 2300
T -199.9 to 400.0 -300 to 750
E -199.9 to 999.9 -300 to 1800
B 0 to 1800 32 to 3300 >400ºC: ±0.15% FS ±1 count
<400ºC: ±5% FS ±1 count
R 0 to 1700 32 to 3100 ±0.15% FS ±1 count
S 0 to 1700 32 to 3100
L -199.9 to 900.0 -300 to 1600 >0ºC: ±0.1% FS ±1 count
<0ºC: ±0.2% FS ±1 count
U -199.9 to 400.0 -300 to 750
N -200 to 1300 -300 to 2400 >0ºC: ±0.1% FS ±1 count
<0ºC: ±0.25% FS ±1 count
W 0 to 2300 32 to 4200 ±0.2% FS ±1 count
Platinel II 0 to 1390 32 to 2500 ±0.1% FS ±1 count
PtA -199.9 to 850.0 -300 to 1560 ±0.1% FS ±1 count
PtB -199.9 to 500.0 -199.9 to 999.9
PtC -19.99 to 99.99 -4.0 to 212.0 ±0.2% FS ±1 count
JPtA -199.9 to 500.0 -199.9 to 999.9 ±0.1% FS ±1 count
JPtB -150.0 to 150.0 -199.9 to 300
*Performance within recommended operating conditions (10 to 50 ºC, 20 to 90% RH)

Process Inputs

Inputs: Field selectable: 0.4 to 2.0 V, 1 to 5 V, 0 to 10 V, -10 to 20 mV, 0 to 100 mV. 4-20 mA input requires 100 Ω resistor connected across input terminals (order P/N: PDX-RES1).
Accuracy: ±0.1% FS ±1 count
Decimal Point: Up to 3 decimals: 9.999, 99.99, 999.9, or 9999
Calibration: All inputs are calibrated at the factory
Scale Range: User programmable over entire range
Transmitter Supply: 14 to 18 VDC @ 20 mA; available instead of retransmitting analog output; selection is made through the front panel.

Alarm Relays

Ratings: 1 Form C (SPDT) standard; rated 3 A @ 30 VDC or 3 A @ 250 VAC resistive load. 1 or 2 Form A (SPST) optional; rated 1 A @ 30 VDC or 1 A @ 250 VAC resistive load
High/Low Alarm: User may program any alarm for absolute high or low operation, forward or reverse (fail-safe) mode.
Alarm Deadband: 0-100% FS, user select
Alarm Delay: 0 to 99 minutes and 59 seconds
Reverse Operation (Fail-Safe): Programmable, independent for each alarm. Relay coils are energized in non-alarm condition. In case of power failure, relays will go to alarm state.
Forward Operation: Relay coils are energized in alarm condition. In case of power failure, relays will go to non-alarm state.
Auto Alarm Initialization: Normal and standby operation independent for each alarm. Normal alarms will reflect the state of the input to the meter at all times. Standby alarms will not trigger if the change to alarm state is a result of power up cycle, set point change, or alarm configuration change.

4-20 mA Retransmitting Output

Scaling Range: 4-20 mA output can be scaled for any display
Accuracy: ±0.1% FS
Power: Internally powered 4-20 mA output
Isolation: 500 V input-to-output
Output Loop Resistance: 600 Ω max

Digital Inputs

Configuration: Two contacts. Two operating modes
Contacts: Normally open switches (external excitation note required) or open collector transistor
Open Circuit Voltage: Approximately 5 VDC
Logic Levels: LO = 0 to 0.8 VDC, HI = 4.7 to 28 VDC
Operation Modes: Mode 1: Store and reset max & min display values simultaneously. Mode 2: Store and reset max & min display values independently.

Serial Communications

Compatibility: EIA-485
Protocol: PC, Modbus (ASCII, RTU)
Address: 1 to 99 (Max 31 units connected)
Baud Rate: 600 to 19,200 bps
Data: 7 or 8 bit, automatic when using Modbus protocol
Transmit Time Delay: 0 to 100 ms
Stop Bit: 1 or 2
Parity: None, even, or odd

Contact Us

“Industrial Technical Services is a single source Instrumentation and Automation company. We provide certified calibrations, PLC programming, custom controls and Panels”.

 

Please fill details below and one of our representative will contact you shortly. 

30 other products in the same category: