SA/CT Modular RTD and Temperature Transmitter

New product
 
More info

The SA modular series RTD elements can be supplied in both stand alone configurations, or along with conduit
wiring housing. All stainless steel design provides a robust platform for use within Food and Dairy processing.

Anderson-Negele’s electronic temperature sensors combine our industry proven, all stainless steel construction with modular components. Interchangeable RTD elements, wiring heads, transmitter modules and digital displays can be individually selected. Components can be factory or field assembled in the optimum configuration for any application.

To further facilitate adaptability, our RTD’s are offered with the widest selection of sanitary clamp, thermowell and flush-mount fittings; and with sealed cable, quick disconnect, or wiring heads options. Our temperature transmitters are available in analog and HART “SMART” versions. These modules can be factory or field installed in any standard (CT) wiring head or panel mounted remotely from the RTD element allowing for greater flexibility.

New Dual Output options provide two signals in virtually any combinations. 

Features

  • Modular components provide maximum configuration flexibility
  • Unique element-to-housing design eliminates exposed threads, lowers profile
  • All stainless steel construction with O-ring seals for maximum corrosion and moisture protection
  • Custom lengths (up to 6”) available at no extra charge
  • Dual Output Options
  • Quick Disconnect Options
 
Specifications
Part No.
SA110040370105
Product Code
SA
Wiring Style
Sealed Cable w/Strain Relief
Element Type
100 ohm Single(DIN stnd.)
Fitting
1-1/2" Tri-Clamp
Insertion Length Selection
Standard
Insertion Length
2.75 INCH
Note
-
Probe
Standard Probe
Cable Type
Multiple Conductor PVC
Connection/Cable
25 ft
A
2 3/4 INCH
B Dia.
1/4 INCH
Accuracy
0.1% at 0°C (Band 1) Standard
Operating Range
Fixed span of 400°F
Low End Temperature Limits
-50°F (-45°C) minimum
High End Temperature Limits
350°F (176°C) maximum
Response Time
2.5 to 3 seconds for 63% step change
Inputs
100 ohm, 3-wire element which conforms to DIN standard (0.00385 ohm/ohm/Deg C). Single element standard; dual element optional
Electrical Connection
Pre-tinned for connection to CT / Pre-tinned sealed cable / M12 Quick Disconnect (configured as 4-wire to minimize output errors from connection resistance)
Process Connections
Various Tri-Clamp, Well and typical fittings found in sanitary applications
Material
316L SS wettable parts
Surface Finish
25 micro-inch Ra (Direct product contact) / 32 micro-inch Ra (Thermowell fittings)
Weight
Varies with fitting, housing style and cable length – consult factory
Compliance/Protection Class
3-A compliant
Warranty
1 year
Spare Parts
29057A0001 1/2" 14Npt Bushing
29057A0002 3/4" 14Npt Bushing

Contact Us