Process inputs:
up to 2 temperature probe inputs
(Note 1)
- PTC KTY81-121 (990 Ω @ 25 °C)
- NTC 103AT-2 (10KΩ @ 25 °C)
Overall accuracy: ± 0,5 % fs + 1 digit
1 digital input
(Note 1)
- Free Voltage
Keyboard
- Mechanical keyboard:
4 multifunction keys
Process outputs:
2 digital outputs
OUT1
- Relay SPST-NO 16A-AC1 6A-AC3 250 VAC
OUT2
- Relay SPST-NO 5A-AC1, 2A-AC3 250 VAC
(Note 1)
Power supply:
- 12 VAC/VDC± 10%
- 24VDC/VAC ± 10%
- 100… 240 Vac (50/60 Hz) ± 10%
Functions:
- Stand-by mode
- ON/OFF control
- Start-up delay
- Compressor protection timer
Defrost
Defrost start/stop:
- Manual
- Time intervals
Defrost methods:
- By compressor stop
- By electrical heater
- By hot gas
- By cycle reverse
Evaporator Fan Control
Alarms
Up to 4 different kind of configurable alarms:
- Probe errors
- Temperature thresholds: (absolute or relative)
- External alarm
- Door alarm
Communication and programming:
Interfaces
Communication on TTL port to:
- Universal programming key
- Remote display
- RS 485 serial interface adapter TLCNV
Programming/configuration tools:
- Easy to use front interface for configuration
- Configuration software available for PC
Installation:
Mounting method: panel mount
Case dimensions: 78 x 35 mm, depth 64 mm
Connections
Signals connection
- 2,5 mm² screw terminals block
Display and indicators
1 display 4 digits, h 12 mm
Red or blue colour
3 LED Bargraph + 5 indicating LEDs
Connectable to:
- Programming key
for PC connection, backup and other functions
- RS 485 serial interface adapter A30
- Remote display TVRY
Notes
1) The second probe input may be used as Free voltage digital input