Applications
- Accessories
- Actuators
- Adapters & Fittings
- Air Eliminator
- Air Filter Regulators
- Analytical Transmitters
- Bench Calibrators
- Blackbody Calibration Sources
- Bulk Tank Recorders
- Calibrators
- Callibrators
- Carbon dioxide Sensors
- Carbon Dioxide Transmitter
- Carbon Monoxide Sensors
- Carbon Monoxide Transmitter
- Chart Recorder
- Chlorine
- Clamp Meters
- Clean Room Panel
- Communicator
- Community Air Monitor
- Compact Bench Scales
- Conductivity
- Conductivity Sensor
- Contact Thermometers
- Controller
- Controllers
- Converters
- Data Logger
- Density
- Dew Point
- Differential Pressure
- Digital Indicators
- Digital Multimeters
- DIN Controllers
- Dissolved Oxygen
- Double Acting
- Dry & Dusty Environments
- Dust Emission Monitors
- Electric Actuators
- Electrical Calibrators
- Electrical Testers
- Electrical Tools
- Ethernet Modbus
- Explosion Proof Bench Scales
- Fieldbus Controller
- Fieldbus Junction Box
- Fixed Temp/Humidity Transmitters
- Flow
- Flow Indicator
- Flow Meter
- FOG Level
- Food Processing Bench Scales
- Gas Alarm/Control System
- Gas Analyzers (Emissions)
- Gas Flow
- Gas Monitor (Air)
- Gas Monitor (Fixed)
- Gas Monitor (Personal)
- Gas Transmitters (toxic gases, combustibles, oxygen)
- Gateway
- Handheld & calibrators
- Handheld Gas Detector
- HMIs
- Humidity/Temperature
- Humidity/Temperature Transmitters
- HVAC/Combustion Analyzers
- Hygrometers
- I/O Modules
- Industrial Emission Analyzers
- Insulation Testers
- IP Converters
- IR Temperature Sensors
- Level
- Level Accessories
- Level Controllers
- Level Indicators
- Level Meters
- Level Monitors
- Level Sensors
- Level Switch/Sensors
- Level Transmitters
- Limit Switch Boxes
- Lock Up Valves
- Magnetic Flowmeter
- Manifolds
- Mass Flow Meter
- Mercury Monitor
- Milk Receiving System
- Modbus
- Moisture
- Moisture Analyzers
- Moisture Sensors
- Multi-Loop Controllers
- Multi-Point Level Switches
- Multifunction Calibrators
- Non-contact Infrared Thermometers
- Noxious Pollutants
- Oxygen Sensors
- Ozone (air monitoring/station)
- Ozone (Ambient)
- Ozone (Calibrators)
- Ozone (Industrial)
- Ozone(Personal)
- Panel Meter
- Paperless Recorders
- pH & ORP
- pH & ORP Analyzers
- pH & ORP Sensors/Probes
- pH, ORP, D.O, Conductivity - Multi Parameter Transmitters
- pH, ORP, D.O, Conductivity - Multi-Parameter Controllers
- Pneumatic
- Pneumatic Pneumatic Positioners
- Point Level Switches
- Position Transmitters
- Positioners
- Positioners - Pneumatic
- Positioners - Smart
- Positioners (Electro Pneumatic)
- Pressure
- Pressure Calibrators
- Pressure Gauges / Indicators
- Pressure Switches - Differential
- Pressure Transmitters
- Pressure/Vacuum Switch
- Process Meters
- Process Recorders
- Programmable Logic Controllers
- Racket
- Recorder
- Refractometer
- Relays
- Repeaters
- Scales (Analytical Balances)
- Scales (Bench)
- Scales (Calibration Weight)
- Scales (Compact Balances)
- Scales (Floor)
- Scales (Indicator)
- Scales (Moisture Analyzer)
- Scales (Platform)
- Scales (Precision Balances)
- Scales (Washdown)
- Sensors/Probes
- Signal Converters/Conditioners
- Single Acting
- Snap Acting Relays
- Sodium And Silicone Analyzers
- Software
- Solenoid Valve
- Surge and Transient Protectors
- Temp/Humidity Switch
- Temperature
- Temperature Calibrators
- Temperature Controllers
- Temperature Gauges
- Temperature Indicators
- Temperature Sensors
- Temperature Switches
- Temperature Transmitters
- Thermal Imagers
- TOC Analyzers
- TOC Measurement
- Totalizer
- Transducers
- Transmitters
- Transmitters
- Tube
- Turbidity
- Turbidity Meter
- Turbidity Sensor
- Ultrasonic Flowmeters
- Valve Positioner Accessories
- Valve Positioners
- Volume Boosters
- Water Activity Measurement
- Weighing Platforms
- Wet & Harsh Environments
- Wireless Products
Industries
Manufacturers
- 2B Technologies
- Adam Equipment Inc.
- Alicat Scientific
- Anderson-Negele
- Aquametrix
- Arkon
- Ascon
- Automa
- Babbitt International
- Brainchild
- Delphian Corporation
- Dickson
- Dwyer Instruments
- Edgetech Instruments
- Eurotron
- Fluke
- Fuji Electric
- Fuzypro
- GFG Instrumentation
- Kytola Instruments
- MadgeTech
- Martel BETA
- Metalogic Technoligies Inc.
- Mettler Toledo
- Precision Digital
- Process Sensors Corporation
- Pyropress
- Rotronic
- Seitron
- SMAR
- Vaisala
- YTC
New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
Test & Measurement
Instruments
106-M Ozone Monitor™(Industrial)
Features
- Recommended for Industrial Ozone Applications for Concentrations in the Range 0-1,000 ppm
- Measurement based on UV absorption
- Low power consumption; can be battery operated
- Internal data logger with real-time clock
The Model 106 series of ozone monitors was designed specifically for the industrial ozone industry to cover four different ozone concentration ranges by varying the optical path length. The ranges are: -L (low, 0-100 ppm); -M (medium, 0-1,000 ppm); -MH (medium high, 0-10,000 ppm, 0-1 vol%) and -H (0-20 wt%, 0-14 vol%). The Model 106 series is designed as an “ozone monitor on a board” in which nearly all of the components are mounted directly to the printed circuit board with very few wire connections, making these instruments highly robust and very easy to service. As seen in the images above, all models are available in a standard enclosure, an Industrial enclosure, or with no enclosure for OEM applications for those who want to mount the instrument in their own enclosure or use it as a component of a larger system. For more details on OEM applications see: Model OEM-106. Configurations for multi-channel sampling are available for Models 106-L, 106-M, and 106-MH.
The Model 106-M Ozone Monitor is designed for measurements of ozone in the range 0-1,000 ppm with a resolution of 0.01 ppm. A common application is off-gas analysis in water treatment plants, before and after ozone destruction.
Application Note
The 0-1000 ppm range of the Model 106-M makes it useful for many industrial and research applications. Below is an example of its use in characterizing lamps used in oxidation flow reactors.