New Product

LT9000
Continous Level Sensor For Conductive Liquid

Continuous measurement of electrically conductive liquids that do not leave a sticky residue or buildup.

Get a quote

The LT9000 level transmitter provides continuous measurement of electrically conductive liquids that do not leave a sticky residue or buildup. Ideal solution for short measuring ranges or tanks and vessels containing obstructions that would normally interfere with non-contact type sensors. Measurement is unaffected by changes in pressure, temperature or media density. No moving parts eliminates break downs, providing maintenance free operations.

Overview

The LT9000 level transmitter utilizes Radio Frequency admittance technology, which measures the change in capacitance between the sensor probe and the vessel wall in order to determine the level. Any change in level causes a capacitance change, which is converted into a 4/20mA output signal. This signal can then be sent to a local display, PLC or other programable controller.

The standard unit is made of a solid stainless-steel probe fully insulated with a non-conductive coating such as HALAR or thick TEFLON SLEEVE – both compatible with a wide variety of aggressive liquids. Inside the explosion proof housing are the sensing electronics and manual calibration adjustment. The isolated 4-20 mA output signal can drive a load of up to 1000 ohms. The zero and span can be set over the entire length of the probe or any portion of the probe

Applications

Continuous level transmission of non-coating, conductive fluids
Liquids:
Water
Acids
Wastewater

Features

  • 4-20 mA output
  • Totally self-contained
  • Temperature stable electronics
  • On Board fuse protection
  • Fully isolated output
  • Simple installation and calibration
  • Modular electronics easily replaced
  • Explosion proof housing standard
  • Two year warranty

Specifications & Spare Parts

Electrical:
Power: 115VAC (+/- 15%) 50/60Hz, or 24VDC
Output: 4-20 mA into a load of 1K ohm max
Fuse: On-board 5A @ 125 volts
Frequency: 10,000 Hz to 300,000 Hz
Environmental:
Hazardous Area: Class I, Group D. Class II, Group E,F,G.
Temperature: Probe: -30 deg F to +340 deg F – Halor
Probe: -30 deg F to +450 deg F – Ryton
Electronics: -40 deg F to 185 deg F
Pressure: 1500 psi @ 75 deg F.
Construction: Probe: All wetted parts 316SS, Viton, Teflon and coating material
Electronics: Housed in cast aluminum explosion-proof enclosure.
LT 9000 Continuous Level Transmitter for Interface and Liquid Level Control

Specifications are subject to change without notice.

 

Product Tags

, , , , , , , ,