New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
PD6720 Vantageview NEMA 4X Loop-Powered Flow Rate Totalizer
The Vantageview PD6720 is a plastic, field-mounted, loop-powered flow rate/totalizer that can display flow rate and total from an analog output (4-20 mA) flowmeter. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines. The display has a five digit upper display for rate, a seven alpha-numeric character lower display for total, and comes standard with a backlight. The PD6720 is built in a NEMA 4X and IP65 rated plastic enclosure which can stand up to even the harshest environmental conditions. Two features that really make it stand out are a wide viewing angle display and SafeTouch® through-window buttons. These buttons allow the PD6720 to be programmed and operated through the cover window, thus eliminating the need to remove the cover in dirty or wet environments.
Features
|
Specifications & Spare Parts
| Display | Upper: Five digits (-9,999 to 99,999) 0.70″ (17.8 mm) high, 7-segment, automatic lead zero blanking. Lower: Seven characters 0.4″ (10.2 mm) high, 14 segment alphanumeric. Symbols: for high & low alarm, password lock. Backlight: white. |
| Display Update Rate | Ambient > -25°C: 2 Updates/Second. Ambient < -25°C: 1 Update/5 Seconds. |
| Display Orientation | Display may be mounted at 90° increments up to 270° from default orientation. |
| Overrange | Display flashes 99,999 |
| Underrange | Display flashes -9,999 |
| Programming Method | Four SafeTouch® through-window buttons when cover is installed. Four internal pushbuttons when cover is removed. |
| Noise Filter | Programmable Lo, Med, Hi, or Off |
| Recalibration | Recalibration is recommended at least every 12 months. |
| Max/Min Display | Max/Min readings reached by the process are stored until reset by the user or until power to the meter is turned off. |
| Password | Programmable password restricts modification of programmed settings. |
| Advanced Functions | Live input calibration, linearization, square root, or programmable exponent. |
| Non-Volatile Memory | All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost. |
| Normal Mode Rejection | 64 dB at 50/60 Hz. |
| Operating Temperature Range | -40 to 75°C. |
| Storage Temperature Range | -40 to 75°C. |
| Relative Humidity | 0 to 90% non-condensing. |
| Connections | Screw terminals accept 12 to 22 AWG wire. |
| Enclosure | NEMA 4X, IP65 plastic field enclosure. Color: grey. Material: Polycarbonate with UV Stabilizer. Three ¾” NPT threaded conduit openings. Two ¾” NPT plastic conduit plugs, with 1.29″ wrenching flats and a screwdriver slot, are included. |
| Mounting | May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½” to 2½” or DN 40 to 65 mm pipe mounting. |
| Overall Dimensions | 5.67″ x 5.25″ x 4.18″ (W x H x D) (144 mm x 133 mm x 106 mm). |
| Weight | 1.65 lbs (26.4 oz, 0.75 kg). |
| Warranty | 3 years parts and labor. |
| Input | Input range: 4-20 mA. Accuracy: ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span. Temperature Drift: 50 PPM/°C. Decimal Point: User selectable decimal point. Calibration Range: An error message will appear if input 1 and input 2 signals are too close together. Maximum Voltage Drop: 3.0 VDC @ 20 mA without loop-powered backlight. 6.0 VDC @ 20 mA with loop-powered backlight. Equivalent Resistance: 150 Ω @ 20 mA without loop-powered backlight. 300 Ω @ 20 mA with loop-powered backlight. Input Overload: Over current protection to 2 A max. |
| Externally Powered Backlight | Voltage Range: 9-30 VDC Maximum Power: 0.2 W @ 9 VDC, 0.25 W @ 12 VDC, 0.5 W @ 24 VDC, 0.75 W @ 30 VDC. |
| Open Collector Output | Rating: Isolated open collector, 30 VDC @ 150 mA max. Alarm Output: Assign as rate alarm or total alarm trip point. Deadband: 0-100% FS, user selectable. Acknowledge: Front panel ENTER button resets output and screen indication. Pulse Output K-Factor: K-factor programmable from 0.0001 to 99999. Pulse Output Frequency: 2, 4, 8, 16, 32, 64, 128 Hz. Minimum pulse width: 3.9 ms @ 128 Hz. Maximum pulse width: 250 ms @ 2 Hz. Factory default pulse width: 31 ms @ 16 Hz. |
| Rate/Totalizer | Rate Display: 0 to 99,999 leading zero blanking. Total Display: 0 to 9,999,999 leading zero blanking. Total Decimal Point: Up to six decimal places or none. Lower Display Configuration: Can be programmed to display total, tag name/engineering units, or to alternate between them. Totalizer: Calculates total based on rate, time base of second, minute, hour, or day, and field programmable multiplier; stored in non-volatile memory upon power loss. Totalizer Reset: Via front panel SafeTouch® button, time delay, external contact closure, or protected. Total Conversion Factor: 0.000001 to 9,999,999. Totalizer Rollover: Display rolls over when display exceeds 9,999,999. Relay status reflects the displayed value. Total Reset Delay: Programmable from 0 to 99,999 seconds. |