New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
GPro 500 Oxygen Gas Sensor for Combustion Control
Features
- Tunable Diode Laser spectroscopy
- Simple installation
- In situ measurement
- SpectraID technology
- Low cost of ownership
- Low nitrogen purging consumption
- Predictive ISM diagnostics
In-situ sensor convenience, with the power of an analyzer
The GPro 500 Oxygen TDL is a unique analyzer that fits anywhere in your process thanks to the broadest range of in situ and on-line process adaptions. It has a proven track record in process and safety applications such as:
Process control
Chlorination and oxychlorination
Flare safety control
Combustion control
ESP filter protection
Vent headers
Vapor recovery
Features and Benefits
Tunable Diode Laser spectroscopy
Dependable, industry-proven technology
Simple installation
Thanks to probe design and single flange connection
In situ measurement
Direct measurements in the gas stream are fast and reliable
SpectraID technology
For highly reliable O2 measurement
Low cost of ownership
No sampling or conditioning equipment. Annual verification and periodic optics cleaning are the only maintenance
Low nitrogen purging consumption
For lower operation costs
Predictive ISM diagnostics
Continually monitor optical path quality to determine when cleaning will be required
Specifications & Spare Parts
| Effective path length | Probes: 100, 200, 400 mm (3.94″, 7.87″, 15.75″) Wafer cell: 50, 80, 100 mm (1.96″, 3.15″, 3.94″)Extractive cell: 200, 400, 800, 1000mm, 10m |
| Lower Detection Limit | 100 ppm-v |
| Measurement range | 0-100% |
| Accuracy | 2% of reading or 100 ppm O2, whichever is greater |
| Linearity | Better than 1% |
| Resolution | <0…01% vol O2 (100 ppm-v) |
| Drift | Negligible (<2% of measurement range between maintenance intervals) |
| Sampling rate | 1 second |
| Response time (T90) | O2 in N2 21% >0% in <2sec |
| Repeatability | ±0,25% of reading or 0,05% O2 (whichever is greater) |
| Process pressure range | 0.8 bar – 5 bar (abs)/11.6 psi – 72.52 psi (abs) |
| Process temperature range | 0-250 ºC(32-482 ºF) Optional(for probe instalation) 0-600 ºC (0-1112 ºF) with additional thermal barrier |