New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
GPro 500 Carbon Monoxide Gas Monitor and Sensor for Combustion Control
Features
- Tunable Diode Laser spectroscopy
- Simple installation
- In situ measurement
- SpectraID technology
- Low cost of ownership
Low nitrogen purging consumption - Predictive ISM diagnostics
The most accurate and reliable instrument for efficient combustion control applications.
The GPro 500 CO TDL is the most accurate and reliable instrument for efficient combustion control applications. By allowing trim control operation mode, the excess air limit can be lowered and adapted to changing conditions without jeopardizing safety. Fast CO monitoring is used in:
Process control
Combustion
Fired heaters
Incinerators
Features and Benefits
Tunable Diode Laser spectroscopy
Dependable, industry-proven technology
Simple installation
Thanks to probe design and single flange connection
In situ measurement
Direct measurements in the gas stream are fast and reliable
SpectraID technology
For highly reliable O2 measurement
Low cost of ownership
No sampling or conditioning equipment. Annual verification and periodic optics cleaning are the only maintenance
Low nitrogen purging consumption
For lower operation costs
Predictive ISM diagnostics
Continually monitor optical path quality to determine when cleaning will be required
Specifications & Spare Parts
| Effective Path Length | Probes: 100, 200, 400 mm (3.94″, 7.87″, 15.75″) Wafer Cell: 50, 80, 100 mm (1.96″, 3.15″, 3.94″) Extractive Cell: 200, 400, 800, 1000 mm, 10 m |
| Lower Detection Limit | 1 ppm-v |
| Measurement Range | 0-20,000 ppm (0-2%) |
| Accuracy | 2% of reading or 1 ppm, whichever is greater |
| Linearity | Better than 1% |
| Resolution | 1 ppm-v |
| Drift | Negligible (<2% of measurement range between maintenance intervals) |
| Sampling Rate | 1 second |
| Response Time (T90) | CO in N2 300 ppm-v to 0% in <4 sec |
| Repeatability | ±0.25% of reading or 5 ppm-v CO (whichever is greater) |
| Process Pressure Range | 0.8 bar – 2 bar (abs)/11.6 psi – 29 psi (abs) |
| Process Temperature Range | 0-250 ºC (32-482 ºF) Optional: 0-600 ºC (0-1112 ºF) with additional thermal barrier |