Features
- Compatible with ALL ROTRONIC HC2 probes
- Range of application: -10 to 60°C / 0 to 100 %RH
- All psychrometric calculations available
- Adjusted at 23°C and 10, 35, 80 %RH
- Service interface (UART)
The HP22 is a versatile hand-held indicator that displays relative humidity, temperature and a variety of calculated parameters such as dew or frost point based on the measurements of a HygroClip 2 plug-in probe.
Probe selection is based on the application. Depending on the HygroClip 2 probe model, the measuring range is within 0 to 100 %RH and -100 to 200°C (-148 to 392°F). The HygroClip 2 probes feature durable sensors and consistent performance. All HygroClip 2 probes can be hot-swapped to facilitate routine calibrations.
The HP22 indicator offers extensive settings and functions that can be enabled and configured by the user either directly from the keypad or with the ROTRONIC HW4 software.
Features
- Compatible with ALL ROTRONIC HC2 probes
- Range of application: -10 to 60°C / 0 to 100 %RH
- All psychrometric calculations available
- Adjusted at 23°C and 10, 35, 80 %RH
- Service interface (UART)
Specifications & Spare Parts
| Probe type | Interchangeable |
| Dimensions | 268 x 72 x 30 mm |
| Operating range electronics | -10…60 °C / 0…100 %RH |
| Accuracy at 23 ±5 °C | Probe dependent |
| Measuring range with interchangeable probe | 0…100 %RH and -50…200 °C |
| Power supply / Power consumption | 9 V battery, power supply 4 mA consumption without back light |
| Long-term sensor stability | <1 %RH / year |
| Humidity sensor | Probe dependent |
| Temperature sensor | Probe dependent |
| Response time t 63 | Probe dependent |
| Allowed wind speed | 20 m/s, with filter |
| Psychrometric calculations | All psychrometric values |
| Number of probe inputs | 1 |
| Calibration / adjustment | multipoint adjustment via keypad |
| Initialisation time | Typically <2 sec. |
| Measurement interval | typically 1 second (without calculations) |
| Display type | Graphic display. Display freely configurable. |
| Backlight | Yes |
| Battery indicator | Low Batt. Display |
| Exploitation software | ROTRONIC HW4.2 |
| Menu guidance | Yes |
| Trend indicator | Yes |
| Statistical functions | Min / Max, Average |
| Probe adjustment by software | Yes, with service cable |
| Probe adjustment by keypad | 1 point or multi-point temperature and humidity adjustment |
| Event logging | System related events (FDA, GAMP) |
| Firmware update | With internet,HW4 software and service cable |
| User information | from Software HW4 (devicemanager) |
| Data processing via HW4 | Yes |
| Device Protection by password | Yes |
| Sensor diagnostics (drift, state) | Programmable; factory default – Off |
| Audit Trail/ electronic records | FDA 21 CFR Part 11 and GAMP compatible |
| External datalogging | 2000 Records |
| Choice of Battery / rechargeable battery | Yes |
| Service Interface | Mini USB (UART) |
| Service Information | Calibration interval |
| Reverse voltage protection | Mechanically in the connector |
| Max. cable length service cable | 5 m |
| Max. probe cable length | 10 m |
| Enclosure material | ABS |
| IP protection rating | IP40 |
| Fire protection class | UL94-HB Compliant |
| FDA/GAMP compatibility | FDA 21 CFR Part 11 and GAMP compatible |