New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
HC2-IExxx-M Stainless Steel Probe For Pressurized Conduits and Vessels
Features
- Range of measurement: -100â¦200 °C, (screw-in probe; -50â¦200 °C) / 0â¦100 %RH
- Digital interface (UART) and scalable analog outputs, 0â¦1 V
- Standard output scaling: 0â¦1 V = -40â¦60 °C / 0â¦100 %RH
- Adjusted at 23 °C and 10, 35, 80 %RH
- Cannot be operated with 2-wire transmitters
This stainless steel industrial probe is especially suitable for high temperatures, demanding industrial environments and areas where hygiene plays an important role. The probe measures humidity and temperature and calculates the dew/frost point.
Features
- Range of measurement: -100â¦200 °C, (screw-in probe; -50â¦200 °C) / 0â¦100 %RH
- Digital interface (UART) and scalable analog outputs, 0â¦1 V
- Standard output scaling: 0â¦1 V = -40â¦60 °C / 0â¦100 %RH
- Adjusted at 23 °C and 10, 35, 80 %RH
- Cannot be operated with 2-wire transmitters
Specifications & Spare Parts
| Probe type | Screw-in probe |
| Weight | 290g |
| Operating range electronics | -50…100 °C / 0…100 %RH |
| Accuracy at 23 ±5 °C | ±0.8 %RH / ±0.1 K |
| Accuracy w. adjustment profile “standard” | at 23 °C / 10, 35, 80 %RH ± 0.8 %RH / ± 0.1 K |
| Power supply / Power consumption | 3.3 V ± 0.1V / ~4.5 mA |
| Long-term sensor stability | <1 %RH / year |
| Humidity sensor | Hygromer IN-1 |
| Temperature sensor | PT100 1/3 DIN Class B |
| Probe protection | Filter carrier, brass nickelplated |
| Filter cartridge | depending on the application, order separately |
| Pressure | Pressure-resistant to 100 bar / 1450 PSI |
| Response time t 63 | <15 sec. |
| Allowed wind speed | 3 m/s |
| Psychrometric calculations | Dew or frost point |
| Connection thread of probe | 1/2″ G / 1/2″ NPT |
| Reproducibility Airchip | <0.02 %RH / 0.01 K |
| Exploitation software | ROTRONIC HW4.2 |
| Probe adjustment by software | 1 Point & multipoint %RH & °C |
| Firmware update | With internet and HW4 software |
| User information | from Software HW4 (devicemanager) |
| Data processing via HW4 | with interface cables |
| Device Protection by password | Yes |
| Type of output signals | 2 x 0…1 VDC |
| Analog outputs scaleable by the user | Yes |
| Analog output signal (standard) | 0…1 V = 0…100 %RH; 0…1 V = -40…60 °C |
| Digital output signal (standard) | UART |
| Service Interface | UART |
| Reverse voltage protection | Mechanically in the connector |
| Max. cable length service cable | 5 m |
| Probe material | Stainless steel 1.4305 (V2A) |
| Probe cable material | FEP, black |
| Enclosure material | Stainless steel 1.4305 (V2A) |
| FDA/GAMP compatibility | FDA 21 CFR Part 11 and GAMP compatible |