New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
HygroFlex5-EX – HF5-EX – two-channel transmitter
Features
- Measurement of relative humidity and temperature, optional output of dew points
and other calculated parameter - Safe operation in areas with explosion risk
- Intrinsically safe probes
- Interchangeable stainless steel probes
- Robust aluminium housing
The new HygroFlex5-EX series is the latest development in two-channel transmitters for the exact measurement of humidity and temperature in explosive atmospheres. This device conforms to the latest international standards. The HF5-EX series consists of a robust aluminium transmitter with or without display. The attached probes are cast into a stainless steel tube, and are certified for operation in Zone 0/20. The transmitter itself is certified for Zone 1/21.
Characteristics:
• Measurement of relative humidity and temperature, optional output of dew points
and other calculated parameter
• Safe operation in areas with explosion risk
• Intrinsically safe probes
• Interchangeable stainless steel probes
• Robust aluminium housing
Specifications & Spare Parts
| Dimensions | 160 x 100 x 61 mm |
| Weight | 1030g / 1140g |
| Operating range electronics | -40…60 °C / -10…60 °C (with display) 0 to 100% rh non-condensing |
| Accuracy at 23 ±5 °C | ±0.8 %rh / ±0.1 K |
| Measuring range with interchangeable probe | 0…100 %rh and -40…85 °C |
| Accuracy analog output | <20 μA |
| Power supply | 10…28 VDC |
| Current consumption | 2×24 mA start up / 2×20 mA operation |
| Humidity sensor | Probe dependent |
| Temperature sensor | Probe dependent |
| Psychrometric calculations | All psychrometric values |
| Number of probe inputs | 1 |
| Start-up time | Standard cold <60 s / warm <30 s |
| Measurement interval | 20…240 s |
| Display type | Optional graphics display. Presentation configurable. |
| Backlight | without Backlight |
| Trend indicator | Yes, for models with display |
| Probe adjustment by software | Not via device menu (only outside the explosive zone with HW4 + AC3001) |
| Firmware update | With internet and HW4 software |
| User information | from Software HW4 (devicemanager) |
| Data processing via HW4 | Graphics, statistics, analysis, qualification, etc. |
| Circuit type | 2 -Wire |
| Analogue outputs scaleable by the user | Yes |
| Analog output signal (standard) | 4…20 mA, two-wire |
| Galvanic separation output signals | Yes |
| Service Interface | UART (internal in device) |
| Probe material | Stainless steel |
| Enclosure material | Aluminum (DIN EN 1706 EN AC-AlSi 12 (Fe)) |
| Cable connections | Connections: Ex-e terminals (0.2…2.5 mm2) Cable gland: 16 x 1.5 (Ø cable 4.5…7 mm) |
| IP protection rating | IP66 |
| FDA/GAMP compatibility | FDA 21 CFR Part 11 and GAMP compatible |
| CE / EMC conform | EMC Directive 2004/108/EC |
| ATEX directives | EU94/9/EC (ATEX) |
| EX identification | EX II 2(1) G Ex eb mb [ia Ga] IIC T5 Gb EX II 2(1) D Ex tb [ia Ga] IIIC T80°C Db |