The ProtEX-RTA PD6820 is an explosion-proof, loop-powered flow rate/totalizer that can display flow rate and total from an analog output (4-20 mA) flowmeter. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area. The display has a five digit upper display for rate, a seven alpha-numeric character lower display for total, and comes standard with a backlight. Like all ProtEX products, the PD6820 explosion-proof flow rate/totalizer carries FM, CSA, ATEX, and IECEx approvals for use in hazardous areas. Two features that really make this flow rate/totalizer stand out are a wide viewing angle display and SafeTouch® through-glass buttons. These buttons allow the PD6820 to be programmed and operated through the glass, thus eliminating the need to remove the cover in a hazardous area.

Features

  • 4-20 mA Input Loop-Powered
  • 5-Digit, 0.7″ (17.8 mm) Upper Display
  • 7 Alphanumeric Character, 0.4″ (10.2 mm) Lower Display
  • Loop or External DC-Powered Backlight Standard
  • SafeTouch Through-Glass Button Programming
  • Password Protection
  • 3.0 V Drop without Backlight
  • Explosion-Proof, IP68, NEMA 4X Enclosure
  • Flanges for Wall or Pipe Mounting
  • Linear, Square Root, or Programmable Exponent
  • Operates from -40 to 75°C
  • Rate in Second, Minute, Hour, or Day
  • Open Collector Pulse or Alarm Output

Specifications & Spare Parts

General
Display Upper: Five digits (-9,999 to 99,999) 0.70″ (17.8 mm) high, 7-segment, automatic lead zero blanking.
Lower: Seven characters 0.4″ (10.2 mm) high, 14 segment alphanumeric.
Symbols: for high & low alarm, password lock.
Backlight: white
Display Update Rate Ambient > -25°C: 2 Updates/Second. Ambient < -25°C: 1 Update/5 Seconds
Display Orientation Display may be mounted at 90° increments up to 270° from default orientation.
Overrange Display flashes 99,999
Underrange Display flashes -9,999
Programming Method Four SafeTouch® through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.
Noise Filter Programmable Lo, Med, Hi, or Off
Recalibration Recalibration is recommended at least every 12 months.
Max/Min Display Max/Min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password Programmable password restricts modification of programmed settings.
Advanced Functions Live input calibration, linearization, square root, or programmable exponent
Non-Volatile Memory All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Normal Mode Rejection 64 dB at 50/60 Hz
Operating Temperature Range -40 to 75°C
Storage Temperature Range -40 to 85°C
Relative Humidity 0 to 90% non-condensing
Connections Screw terminals accept 12 to 22 AWG wire
Enclosure Explosion-proof die-cast aluminum with glass window, corrosion-resistant epoxy coating, color: blue. NEMA 4X IP68. Copper-free (0.3%). Two ¾” NPT threaded conduit openings. One ¾” NPT metal conduit plug with 12 mm hex key fitting installed.
Mounting May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½” to 2½” or DN 40 to 65 mm pipe mounting.
Overall Dimensions 5.65″ x 5.25″ x 4.86″ (W x H x D) (144 mm x 133 mm x 124 mm)
Weight 5.00 lbs (80 oz, 2.27 kg)
Warranty 3 years parts and labor
Input
Input range 4-20 mA
Accuracy ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span.
Temperature Drift 50 PPM/°C
Decimal Point User selectable decimal point
Calibration Range An error message will appear if input 1 and input 2 signals are too close together.
Input Range: 4-20 mA. Minimum Span Input 1 & Input 2: 0.10 mA
Maximum Voltage Drop 3.0 VDC @ 20 mA without loop-powered backlight.
6.0 VDC @ 20 mA with loop-powered backlight
Equivalent Resistance 150 Ω @ 20 mA without loop-powered backlight.
300 Ω @ 20 mA with loop-powered backlight
Input Overload Over current protection to 2 A max.
Externally Powered Backlight —
General
Display Upper: Five digits (-9,999 to 99,999) 0.70″ (17.8 mm) high, 7-segment, automatic lead zero blanking. Lower: Seven characters 0.4″ (10.2 mm) high, 14 segment alphanumeric. Symbols: for high & low alarm, password lock. Backlight: white
Display Update Rate Ambient > -25°C: 2 Updates/Second. Ambient < -25°C: 1 Update/5 Seconds
Display Orientation Display may be mounted at 90° increments up to 270° from default orientation.
Overrange Display flashes 99,999
Underrange Display flashes -9,999
Programming Method Four SafeTouch® through-glass buttons when cover is installed. Four internal pushbuttons when cover is removed.
Noise Filter Programmable Lo, Med, Hi, or Off
Recalibration Recalibration is recommended at least every 12 months.
Max/Min Display Max/Min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Password Programmable password restricts modification of programmed settings.
Advanced Functions Live input calibration, linearization, square root, or programmable exponent
Non-Volatile Memory All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Normal Mode Rejection 64 dB at 50/60 Hz
Operating Temperature Range -40 to 75°C.
Storage Temperature Range -40 to 85°C.
Relative Humidity 0 to 90% non-condensing
Connections Screw terminals accept 12 to 22 AWG wire
Enclosure Explosion-proof die-cast aluminum with glass window, corrosion-resistant epoxy coating, color: blue. NEMA 4X IP68. Copper-free (0.3%). Two ¾” NPT threaded conduit openings. One ¾” NPT metal conduit plug with 12 mm hex key fitting installed.
Mounting May be mounted directly to conduit. Two slotted flanges for wall mounting or NPS 1½” to 2½” or DN 40 to 65 mm pipe mounting.
Overall Dimensions 5.65″ x 5.25″ x 4.86″ (W x H x D) (144 mm x 133 mm x 124 mm)
Weight 5.00 lbs (80 oz, 2.27 kg)
Warranty 3 years parts and labor
Input
Input range 4-20 mA
Accuracy ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range: 10-100% of calibrated span.
Temperature Drift 50 PPM/°C
Decimal Point User selectable decimal point
Calibration Range An error message will appear if input 1 and input 2 signals are too close together.
Input Range: 4-20 mA. Minimum Span Input 1 & Input 2: 0.10 mA
Maximum Voltage Drop 3.0 VDC @ 20 mA without loop-powered backlight.
6.0 VDC @ 20 mA with loop-powered backlight
Equivalent Resistance 150 Ω @ 20 mA without loop-powered backlight.
300 Ω @ 20 mA with loop-powered backlight
Input Overload Over current protection to 2 A max.
Voltage Range
Voltage Range 9-30 VDC
9 VDC 0.2 W
12 VDC 0.25 W
24 VDC 0.5 W
30 VDC 0.75 W
Open Collector Output
Rating Isolated open collector, 30 VDC @ 150 mA max.
Alarm Output Assign as rate alarm or total alarm trip point.
Deadband 0-100% FS, user selectable
Acknowledge Front panel ACK button resets output and screen indication.
Pulse Output K-Factor K-factor programmable from 0.0001 to 99999.
Pulse Output Frequency 2, 4, 8, 16, 32, 64, 128 Hz. Minimum pulse width: 3.9 ms @ 128 Hz. Maximum pulse width: 250 ms @ 2 Hz. Factory default pulse width: 31 ms @ 16 Hz
Rate/Totalizer
Rate Display 0 to 99,999 leading zero blanking
Total Display 0 to 9,999,999 leading zero blanking
Total Decimal Point Up to six decimal places or none: d.dddddd, d.ddddd, d.dddd d.ddd, d.dd, d.d, or ddddddd
Lower Display Configuration Can be programmed to display total, tag name/engineering units, or to alternate between them.
Totalizer Calculates total based on rate, time base of second, minute, hour, or day, and field programmable multiplier; stored in non-volatile memory upon power loss.
Totalizer Reset Via front panel SafeTouch® button, time delay, external contact closure, or protected
Total Conversion Factor 0.000001 to 9,999,999
Totalizer Rollover Display rolls over when display exceeds 9,999,999. Relay status reflects the displayed value.
Total Reset Delay Programmable from 0 to 99,999 seconds
Product Ratings & Approvals
FM Explosion-proof for use in Class I, Division 1, Groups B, C, D. Class II, Division 1, Groups E, F, G. Class III, Division 1; T6. Class I, Zone 1, AExd IIC T6 Gb. Zone 21, AEx tb IIIC T85°C. Ta = -40 to 75°C. Enclosure: Type 4X & IP66. Certificate number: 3040391
ATEX II 2 G D. Ex d IIC T6 Gb. Ex tb IIIC T85°C Db IP68. Ta = -40 to 75°C. Certificate number: Sira 10ATEX1116X
IECEx IECEx SIR 10.0056X. Ex d IIC T6 Gb. Ex tb IIIC T85 C Db IP68. Ta = -40 to 75°C
CSA Class I, Division 1, Groups B, C, D. Class II, Division 1, Groups E, F, G. Class III, Division 1; T6. Class I, Zone 1, Ex d IIC T6. Ta = -40 to 75°C. Enclosure: Type 4X & IP66. Certificate number: 11 2325749