New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
PD6363 ProVu Dual Pulse Input Flow Flow Rate
Related Products
The PD6363 is a member of the ProVu series of 1/8 DIN digital panel meters that is specifically designed to display flow rate and total from two (2) pulse output (NPN, PNP, TTL, switch contact, sine wave, etc.) flowmeters. It displays these signals on a dual-line, 6-digit display that is available with optional Sunbright® sunlight readable LEDs. The dual-line display can be used to show both flow rates simultaneously, to alternate between the two inputs showing both the flow rate and total of each, or to show the result of math functions performed on the flow rates and totals. Like all ProVu meters, the PD6363 includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options. ProVu meters can be equipped with up to four internal relays, a 4-20 mA output, and Modbus® RTU serial communications. The PD6262 dual-input flow rate/totalizer includes a 24 VDC power supply to drive the flowmeter and can be programmed via the front panel pushbuttons or free MeterView® Pro software.
Features
|
Specifications & Spare Parts
General Specifications |
|
|---|---|
| Display | Upper display: 0.60″ (15 mm) high. Lower display: 0.46″ (12 mm) high. 6 digits each (-99999 to 999999), red LEDs with lead zero blanking. |
| Display Intensity | Eight user selectable intensity levels. |
| Display Update Rate | (PD6262): 5/second (200 ms), (PD6363): Rate: 10 per second; up to 1 per 100 seconds (function of Low Gate setting); Total: 10 per second (fixed). |
| Overrange/Underrange | Display flashes 999999 (Overrange), Display flashes -99999 (Underrange). |
| Display Assignment | Upper and lower displays may be assigned to show one or more rate channels, totals, grand total, relay set points, max/min values, and Modbus inputs. |
| Programming Methods | Four front panel buttons, digital inputs, PC, MeterView Pro software, and Modbus registers. |
| Max/Min Display | Max/min readings stored until reset or power cycle. |
| Password Protection | Three programmable passwords restrict modification and resetting totals, with additional settings for total and grand total resets. |
| Noise Filter | (PD6262) Programmable from 2 to 199 (0 disables the filter). |
| Filter Bypass | (PD6262) Programmable from 0.1 to 99.9% of the calibrated span. |
| Non-Volatile Memory | Stores settings for a minimum of ten years. |
| Recalibration | Factory calibrated; recommended recalibration every 12 months. |
| Power Options | 85-265 VAC 50/60 Hz, 90-265 VDC, or 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration. |
| Fuse | UL Recognized, 5 A max, slow blow. Up to 6 meters may share one 5 A fuse. |
| Isolation | 4 kV input/output-to-power line. 500 V input-to-output or output-to-P+ supply. |
| Overvoltage Category | Installation Overvoltage Category II. |
| Environmental | Operating temp: -40 to 65°C, Storage temp: -40 to 85°C, Humidity: 0 to 90% non-condensing. |
| Connections | Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters. |
| Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, black. |
| Dimensions | 4.68″ x 2.45″ x 5.64″ (119 mm x 62 mm x 143 mm) (W x H x D). |
| Weight | 9.5 oz (269 g). |
| Warranty | 3 years parts & labor. |
| USB Connection | Compatibility: USB 2.0 Standard, Cable: USB A Male to Micro-B Cable, Power: USB Port. |
Dual Input Functionality |
|
| Analog Inputs | (PD6262) Two inputs, field selectable: 0-20, 4-20 mA, ±10 V, Modbus PV (Slave). |
| Pulse Inputs | (PD6363) Two inputs, selectable: Pulse or square wave, TTL, open collector, NPN/PNP transistor, Modbus PV (Slave). |
| Low Voltage Mag Pickup | (PD6363) Sensitivity: 40 mVp-p to 8Vp-p. |
| Calibration Range | (PD6262) Minimum span for 4-20 mA: 0.15 mA, ±10 V: 0.10 V. (PD6363) Minimum span between inputs: 10 Hz. |
Dual Rate/Totalizer |
|
| Rate Display Indication | 0 to 999999, lead zero blanking. |
| Total Display & Overflow | 0 to 999,999, with total-overflow up to 999,999,999. |
| Dual Totalizer | Calculates total for channels A and B with field programmable multiplier for engineering units. |
Relays |
|
| Rating | 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load. |
| Relay Assignment | Relays may be assigned to channel A/B rate, total, grand total, channel C, or Modbus control. |
Isolated 4-20 mA Transmitter Output |
|
| Output Source | Input channels A/B, rate, total, grand total, channel C, set points, or manual control. |
| Scaling Range | 1.000 to 23.000 mA for any display range. |
| Accuracy | ±0.1% FS ±0.004 mA. |
Serial Communications |
|
| Protocol | Modbus® RTU. |
| Baud Rate | 300 – 19,200 bps. |
| Data | 8 bit (1 start bit, 1 or 2 stop bits). |
Digital I/O Expansion Module |
|
| Channels | 4 digital inputs & 4 digital outputs per module. |
| System | Up to 2 modules for a total of 8 inputs & 8 outputs. |
4-Relay Expansion Module |
|
| Relays | Four Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load. |
Dual Analog Output Expansion Module |
|
| Outputs | Two passive 4-20 mA analog outputs. |
| Scaling Range | 3.000 to 23.000 mA for any display range. |