PD689 Loop Leader Loop-Powered Intrinsically Safe
The Loop Leader PD689 is an Intrinsically Safe and Nonincendive, loop-powered, 1/8 DIN flow rate/totalizer designed for hazardous process control applications. The fact that this meter is loop-powered means that there is no need to run additional, costly power lines into a hazardous area; the meter gets all of the power it needs from the 4-20 mA loop. The PD689 loop-powered rate/totalizer is built in a shallow-depth case with an FM Type 4X front and features loop-powered backlighting and a wide -30 to 65°C operating temperature range. It doesn’t matter if it’s indoors or outdoors, in bright sunlight or a dimly lit plant, or in an area that is wet, dirty, hot, or cold, the Loop Leader can go just about anywhere. The PD689 can be installed in just about any hazardous area environment under the FM, CSA, and ATEX standards.
Features
|
Specifications & Spare Parts
General
| Display | 5-digit LCD (-99999 to 99999), 0.60″ (15.2 mm) high, 7-segment, automatic lead zero blanking. |
| Engineering Units | 0.25″ (6.4 mm) high, 14-segment. |
| Bargraph | 20-segment, 0% to 100% indication. |
| Trend Arrows | Up and down trend indication. |
| Backlight | Bright orange (intensity varies with signal) |
| Front Panel | FM Type 4X, IP65; panel gasket provided |
| Display Update Rate | 2.5/second |
| Overrange | Display flashes 99999 |
| Underrange | Display flashes -99999 |
| Programming Method | Four front panel buttons |
| Noise Filter | Programmable from 1 to 199 |
| Recalibration | Recommended at least every 12 months. |
| Max/Min Display | Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off. |
| Password | Programmable password restricts modification of programmed settings. |
| Non-Volatile Memory | All programmed settings are stored in nonvolatile memory for a minimum of ten years if power is lost. |
| Voltage Drop | 2.0 V max w/o backlight, 5.7 V max with backlight |
| Equivalent Resistance | 125 Ω @ 20 mA without backlight, 315 Ω @ 20 mA with backlight. |
| Normal Mode Rejection | 64 dB at 50/60 Hz |
| Operating Temperature Range | -20 to 65°C |
| Allowable Temperature Range | -40 to 65°C |
| Storage Temperature Range | -40 to 85°C |
| Relative Humidity | 0 to 90% non-condensing |
| Connections | Screw terminals accept 12 to 22 AWG wire |
| Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: gray |
| Mounting | 1/8 DIN panel cutout required. Two panel mounting bracket assemblies provided. |
| Tightening Torque | 4.5 lb-in (0.5 Nm) Screw terminal connectors |
| Overall Dimensions | 4.68″ x 2.45″ x 3.79″ (119 x 62 x 96 mm) |
| Weight | 5.7 oz (162 g) |
| Warranty | 3 years parts & labor |
Input
| Input Range | 4-20 mA |
| Accuracy | ±0.03% of span ±1 count, square root and programmable exponent: 10-100% FS. |
| Calibration | Scale without signal or calibrate with signal source |
| Calibration Range | User programmable over entire range of meter |
| Minimum Span | 0.40 mA between input 1 and input 2 |
| Input Overload | Over current protection to 2 A max. |
| Decimal Point | Up to 4 places (d.dddd, dd.ddd, ddd.dd, dddd.d, or ddddd) |
| Function | Linear, square root, or programmable exponent |
| Low-Flow Cutoff | -99999 to 99999 (-99999 disables cutoff function) |
| Temperature Drift | 50 PPM/°C from -40 to 65°C ambient |
Totalizer Features
| Total Display | 0 to 99,999 main total display plus 0 to 999 total overflow for a combined 8 digit total of 99,999,999. |
| Alternating Display | Display may be programmed to alternate between rate and total every 10 seconds. |
| Time Base | Seconds, minutes, hours, or days |
| Totalizer Conversion Factor | 0.0001 to 99999 |
| Totalizer | Calculates total based on rate, time base of second, minute, hour, or day, and field programmable multiplier; stored in non-volatile memory upon power loss. |
| Totalizer Rollover | Total rolls over when total exceed 99,999,999. |
| Totalizer Reset | Manual reset or automatic with time delay, or disabled for non-resettable total applications. |
Open Collector Output
| Rating | Isolated open collector, 30 VDC @ 175 mA max. |
| Alarm Output | Assign to rate or total, high or low rate alarm. |
| Deadband | 0-100% of full scale, user selectable |
| Acknowledge | ACK button resets output and screen indication. |
| Automatic Reset | Alarm resets automatically when signal reaches the reset point. |
| Pulse Output | 250 pulses/sec max; pulse width: 3 ms, fixed. One pulse per total increment, programmable from 0.0001 to 99999. |
PD689 Approvals for Hazardous Locations
| FM Approved & CSA Certified | Intrinsically safe with entity for use in Class I, Div 1, Groups ABCD; Class II, Div 1, Groups EFG; Class III, Div 1; Class I, Zone 0, Group IIC; T-code = T4. |
| ATEX | II 1G, Ex ia IIC T4, IP65, Ta = -40°C to 65°C |