The ProVu PD6310 is an 1/8 DIN pulse input (NPN, PNP, TTL, switch contact, sine wave, etc.) digital batch controller specifically designed for single and multi-stage batching applications. It provides excellent but simple batch control capabilities with features such as preclose relays and automatic overrun correction for more accurate batches and intuitive front panel buttons for simple operation and menu navigation. The preclose deactivates a specific relay on the batch controller before the batch is finished in order to allow slower fill rates and increased accuracy. Automatic overrun correction keeps the batch size accurate over time and with system wear. With expansion module relays, up to eight-stage batching is possible; each additional stage-batching relay has an individually programmable preclose amount. Like all ProVu meters, the PD6310 batcher includes UL / C-UL listing and CE marking, a NEMA 4X front, and AC or DC power options.
Features
|
Specifications & Spare Parts
General Specifications |
|
|---|---|
| Display | Upper: 0.60″ (15 mm), Lower: 0.46″ (12 mm), Both are 6 digits (-99999 to 999999), red LEDs, lead zero blanking. |
| Default Display Assignment | Upper: batch total, Lower: rate (alternating units, grand total, batch count, preset switchable). |
| Custom Display Assignment | Rate, total, grand total, batch count, preset, set points, units, alternating R & T, alternating R & GT. |
| Display Intensity | Eight user-selectable intensity levels. |
| Display Update Rate | 5 times per second (200 ms). |
| Overrange/Underrange | Overrange: Display flashes 999999, Underrange: Display flashes -99999. |
| Front Panel | NEMA 4X, IP65 rated. |
| Power Options | 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or 12-24 VDC ± 10%, 15 W max. |
| Fuse | UL Recognized, 5 A max, slow blow; up to 6 controllers may share one 5 A fuse. |
| Isolation | 4 kV input/output-to-power line; 500 V input-to-output or output-to-P+ supply. |
| Environmental | Operating temp: -40 to 65°C; Storage temp: -40 to 85°C; Humidity: 0 to 90% non-condensing. |
| Connections | Removable screw terminal blocks (12 to 22 AWG), RJ45 for external relays, digital I/O, and serial communication adapters. |
| Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black. |
| Dimensions | 4.68″ x 2.45″ x 5.64″ (119 mm x 62 mm x 143 mm) (W x H x D). |
| Weight | 9.5 oz. (269 g). |
PD6210 Analog Input |
|
| Inputs | Field selectable: 0-20, 4-20 mA, ±10 VDC (0-5, 1-5, 0-10 V), Modbus PV (Slave). |
| Accuracy | ±0.03% of calibrated span ±1 count, square root & programmable exponent accuracy range. |
| Temperature Drift | 0.005% of calibrated span/°C max from 0 to 65°C ambient. |
| Multi-Point Linearization | 2 to 32 points. |
| Low-Flow Cutoff | 0-999999 (0 disables cutoff function). |
| Input Impedance | Voltage ranges: greater than 1 MΩ. Current ranges: 50 – 100 Ω (depending on resettable fuse impedance). |
PD6310 Pulse Input |
|
| Inputs | Pulse or square wave 0-5 V, 0-12 V, or 0-24 V @ 30 kHz; TTL; open collector 4.7 k Ω pull-up to 5 V @ 30 kHz. |
| Minimum Input Frequency | 0.001 Hz, dependent on high gate setting. |
| Maximum Input Frequency | 30,000 Hz (10,000 for Low Voltage Mag Pickup). |
| K-Factor | Field programmable, converts input pulses to rate in engineering units (0.00001 to 999,999 pulses/unit). |
Batch Controller |
|
| Rate Display Indication | 0 to 999999, lead zero blanking. “R” LED illuminates while displaying rate. |
| Batch Preset | 0.00001 to 999,999 based on batch total decimal point. |
| Grand Total Alarms | Up to seven, user-selectable under Setup menu. Any set point can be assigned to grand total for alarm indication. |
| Grand Total Reset | Via front panel button, external contact closure, serial communications. |
| Automatic Batch Restart Delay | 00000.1 to 999.9 seconds. |
Relays |
|
| Rating | 2 or 4 SPDT (Form C) internal and/or 4 SPST (Form A) external; rated 3 A @ 30 VDC and 125/250 VAC resistive load. |
| Preclose | 0-100% of batch size, individually programmable for each additional batch control relay beyond the first. |
Isolated 4-20 mA Transmitter Output |
|
| Output Source | Rate/process, total, grand total, max, min, set points 1-8, Modbus input. |
| Scaling Range | 1.000 to 23.000 mA for any display range. |
| Accuracy | ±0.1% FS ±0.004 mA. |
| Output Loop Resistance | 24 VDC: 10Ω min, 700Ω max; 35 VDC external: 100Ω min, 1200Ω max. |
Serial Communications |
|
| Protocol | Modbus® RTU. |
| Baud Rate | 300 – 19,200 bps. |
| Data | 8 bit (1 start bit, 1 or 2 stop bits). |
Digital I/O Expansion Module |
|
| Channels | 4 digital inputs & 4 digital outputs per module. |
| System | Up to 2 modules for a total of 8 inputs & 8 outputs. |
4-Relay Expansion Module |
|
| Relays | Four Form A (SPST) rated 3 A @ 30 VDC and 125/250 VAC resistive load; 1/14 HP (50 watts) @ 125/250 VAC for inductive loads. |