New Product
Ozone (Ambient) / Chemical & Petrochemical / Pharma / Water & Waste Water
Model 205 Dual Beam Ozone Monitor High
Ozone (Industrial) / Chemical & Petrochemical / Pharma / Water & Waste Water
106-MH Ozone MonitorTM (Industrial)
Ozone (Industrial) / Automotive & Manufacturing / Chemical & Petrochemical / Dairy / Food & Beverage / Lab & Gas / Pharma / Plastics / Power & Steam
106-HIndustrial Ozone MonitorTM
D9 Two Independent Channels Acqusition DIN Rail Mount Module
Related Products
Features
- Compact dimensions: 22.5 mm width, 99 mm length
- 2 Configurable process inputs
- 1 digital input
- 2 digital outputs
- 2 additional configurable digital inputs or outputs
- Dual input acquisition module with digital outputs
- Power supply and RS485 communication on side bus
- Withdrawable electronic, configuration and parameters back-up for easy replacement and maintenance
Specifications & Spare Parts
| Specifications | |
|---|---|
| Process Inputs | 2 universal inputs – Thermocouples: L, J, T, K, S, R, B, N, E, Ni-NiMo, W3, W5 – RTD: Pt100 – Voltage (mV): 0/10…50 mV – Current (mA): 0/4…20 mA (with 2.5 Ω shunt resistor) – Custom linearisation and IR probes (J.K type) Accuracy: 0.25% ±1 digit (probes) or 0.1% ±1 digit (mA or mV) |
| Digital Inputs | 1 digital input 2 additional configurable digital inputs or outputs: – NPN – TTL – Free Voltage |
| Process Outputs | 2 digital outputs 2 additional configurable digital inputs or outputs:OUT1 – RELAY SPST-NO, 2A (250VAC) – TRIAC 1A 250 VACOUT2 – RELAY SPST-NO, 2A (250VAC) – TRIAC 1A 250 VAC OUT3/OUT4 |
| Power Supply | 24VDC/VAC Transmitter power supply: 18 Vdc ±20%, 30 mA Max |
| Functions | – Configuration and parameters back-up and automatic restore (with DX master) |
| Alarms | Up to 4 configurable alarms |
| Communication and Programming | Interfaces: – RS 485 port with ModBus RTU and J-bus (slave) protocolsProgramming/configuration tools: – Configuration software available for PC |
| Installation | Mounting method: DIN rail mount Case dimensions: 22.5 x 99 mm, depth 114.5 mm |
| Connections | Communication ports: – RS485 on male and female side bus connectionSignals connection: – 4 Extractable polarized 4 pole screw plugs, 2.5 mm² – Withdrawable electronic without un-wiring signals, power supply and communication bus |
| Connectable to | – Deltadue Series – SCADA for monitoring, traceability, and remote management – DX and DY gateways for remote monitoring |
| Used for | – Multiloop data acquisition and process control |